Serve For Real Test

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsCoal Coke Analysis Instruments

Automatic calorimeter oxygen bomb method ISO 1928

Automatic calorimeter oxygen bomb method ISO 1928

    • Automatic calorimeter oxygen bomb method ISO 1928
    • Automatic calorimeter oxygen bomb method ISO 1928
  • Automatic calorimeter oxygen bomb method ISO 1928

    Product Details:

    Place of Origin: China
    Brand Name: SRI
    Certification: ISO 9001:2000
    Model Number: MJ-CV-OB

    Payment & Shipping Terms:

    Minimum Order Quantity: 1set
    Price: 5000-15000USD/set
    Packaging Details: Standard exporting package
    Delivery Time: 10-15 working days
    Payment Terms: T/T, L/C, PAYPAL
    Supply Ability: 50 sets/month
    Minimum Order Quantity: 1set
    Contact Now
    Detailed Product Description
    Function: Calorific Value Test Method: Oxygen Bomb Method
    Standards: ISO 1928 Category: Coal Coke Analysis Instrument

    Standards

    ISO 1928-1995, GB/T213

     

    The automatic calorimeter is specially used to determine the calorific value of coal, coke, petroleum, solid waste, cement black raw meal and other combustible substances.

     

    Features

    ◎ Five probes are used for real-time temperature sensing. During the test, the external cylinder, the internal cylinder, the temperature regulating water tank, the thermostatic water tank and the room temperature are detected in real time, so as to truly realize the automatic temperature adjustment of the internal and external cylinders;

    ◎ The MCPC control module is used to monitor the status of the instrument in real time, save the instrument parameters, and the test process is completed independently without the intervention of the upper computer, realizing offline operation and self diagnosis reminder of the instrument, greatly improving the reliability of the instrument;

    ◎ New automatic oxygen charging and venting device and automatic lifting mechanism of oxygen bomb are adopted, which can automatically lift and release oxygen, with high degree of automation and simple and convenient operation;

    ◎ The automatic identification technology of oxygen bomb is adopted to automatically distinguish the heat capacity of different oxygen bombs;

    ◎ The pump circulation mode is adopted to make the temperature of each point of the whole calorimetric system of the instrument fairly balanced, so as to ensure the accuracy of the test results;

    ◎ Thermal insulation materials are used to isolate the influence of external environment, and the instrument has strong anti-interference ability;

    ◎ The probe type electronic measuring cup is used to automatically measure the water volume of the inner cylinder. The repetition error is less than 0.5g, and the water volume of the inner cylinder is accurate and stable. The test time is short and the results are accurate;

    ◎ Automatic judgment function of ignition wire, which can accurately judge the bad state of ignition wire;

    ◎ Digital barometer is used to facilitate observation;

    ◎ Filter device for test water is used to prevent impurities from blocking the water path;

    ◎ According to the working conditions of the laboratory, it can be converted from desktop to vertical structure;

    ◎ It can be connected to the laboratory management system to ensure that the balance data does not fall to the ground, and the test results are backed up and uploaded;

    ◎ For solid waste samples, special oxygen bomb, crucible and other accessories can be selected;

    ◎ The optional oxygen bomb gas collection device is used to collect the gas in the oxygen bomb.

     

    Specifications

    Model MJ-CV-OB-6 MJ-CV-OB-5 MJ-CV-OB-4
    Temperature measuring range 5℃~40℃ 5℃~40℃ 5℃~40℃
    Precision RSD≤0.1% RSD≤0.1% RSD≤0.1%
    Thermal capacity stability Change of heat capacity within one year≤0.2% Change of heat capacity within one year≤0.2% Change of heat capacity within one year≤0.2%
    Accuracy Better than accuracy required in standard Better than accuracy required in standard Better than accuracy required in standard
    Temperature resolution 0.0001℃ 0.0001℃ 0.0001℃
    Single sample test time ≤13min(traditional method),≤10min(fast) ≤13min(traditional method),≤10min(fast) ≤13min(traditional method),≤10min(fast)
    Temperature sensing technology
    Oxygen bomb identification /
    MCPC module /
    Water level visibility /
    Oxygen charging mode Automatic Manual Automatic
    Exhaust mode Automatic Manual Automatic
    Lifting cover opening Automatic Automatic Automatic
    Water volume of outer barrel 22L 22L 22L
    Refrigerating water volume 12L 12L 8L
    Refrigeration mode Semi-conductor Semi-conductor Compressor
    Placement method Desktop, vertical Desktop, vertical Desktop
    Working power supply AC220V±22V/50Hz    
    Power ≤0.8 kW   0.5kw
    Overall dimension (mm) 980×520×500   830×460×470
    Total weight 115 kg 105 kg 77 kg

     

    Model MJ-CV-OB-3 MJ-CV-OB-2 MJ-CV-OB-1
    Temperature measuring range 5℃~40℃ 5℃~40℃ 5℃~40℃
    Precision RSD≤0.1% RSD≤0.1% RSD≤0.1%
    Thermal capacity stability Change of heat capacity within one year≤0.2% Change of heat capacity within one year≤0.2% Change of heat capacity within one year≤0.2%
    Accuracy Better than accuracy required in standard Better than accuracy required in standard Better than accuracy required in standard
    Temperature resolution 0.0001℃ 0.0001℃ 0.0001℃
    Single sample test time ≤13min(traditional ),≤10min(fast) ≤13min(traditional ),≤10min(fast) ≤13min(traditional ),≤10min(fast)
    Temperature sensing technology /
    Oxygen bomb identification / /
    MCPC module / /
    Water level visibility / /
    Oxygen charging mode Manual Manual Manual
    Exhaust mode Manual Manual Manual
    Lifting cover opening Automatic Manual Manual
    Water volume of outer barrel 22L 22L 22L
    Refrigerating water volume 8L 12L 6L
    Refrigeration mode Compressor Semi-conductor Semi-conductor
    Placement method Desktop, vertical Desktop, vertical Desktop
    Working power supply AC220V±22V/50Hz AC220V±22V/50Hz AC220V±22V/50Hz
    Power ≤0.5kW ≤0.8kW 0.5kw
    Overall dimension (mm) 830×460×470 980×520×480 720×460×420
    Total weight 76kg 90kg 45kg

     

     

    Automatic calorimeter oxygen bomb method ISO 1928 

     

                    Automatic calorimeter oxygen bomb method ISO 1928

    Contact Details
    Serve Real Instruments Co.,Ltd

    Contact Person: Mr. Patrick

    Tel: 00-86-18014755745

    Fax: 86-86-18621861107

    Send your inquiry directly to us (0 / 3000)

    Request A Quote

    E-Mail | Sitemap

    Privacy Policy | China triaxial test machine Supplier. Copyright © 2016 - 2025 civil-instruments.com. All Rights Reserved. Developed by ECER